- Ozone Generation
Silent pulse injection corona discharge.
Ozone Production
4g/h from dry air at 5 L/min air flow. (1 L/min = 2 SCFH)
Air Drying
Two automatically recharged alumina desiccant cylinders. Vacuum
driven.
Dry Air Capacity
Up to 8 L/min (16 SCFH) ambient air at 85% R.H. 35°C.
Resulting Dew Point
-40°C or better. Dew point indicator (blue crystals) included. -
- Cooling
Ambient air ± 40°C max. 85% R.H.
Power
120V/60Hz or 230V/50Hz, 120W.
Dimensions
514mm high x 305mm wide x 196mm deep (21"x 12"x 8") powder coated
NEMA style steel cabinet with holes for wall mounting.
Warnock & Hersey Certified
CSA file L18014 - Canada
ETL file #98260 - USA
Safety
Internal air flow switch. The unit is protected against voltage
surges and continuous 150% overvoltage. The Balance Barometer is
required with all water treatment installations.
Warranty
3 years general. The rate of the air drying desiccant depletion is
subject to local air quality, and it is expected to last 3 years in normal
conditions. Premature depletion of the desiccant is not covered under warranty.
Installation
Refer to installation manual.
Operation
In conjunction with mixing systems, and other equipment approved by
the Application Engineering Department.
|